Qualification Summary - Prague CU

March 31, 2004

Module Result Comments
20220990290385  PASS 9 additional bad channels
20220990290407  FAIL 27 additional bad channels, suspect IV, FullBypass Test FAIL, noise bumps
20220990290408  PASS 6 additional bad channels, BLG at SD fraction of 0.25, disappears at 0.40, difficult to cool
20220990290409  PASS 1 additional bad channel, no unbonded channels
20220990290410  PASS 12 additional bad channels

Module 20220990290385 - S001

Visual Inspection:

Comments:

Electrical Tests

Test Name  Result  Comment
Long Term Test PASS  
FullBypassTest PASS  
RedundancyTest PASS  
Pipeline Test PASS  
StrobeDelay PASS  
ThreePointGain FAIL 21 bad strips
TrimRangeScan FAIL 17 bad strips
ResponseCurve FAIL 21 bad strips
NO PASS  
TimeWalk PASS  
IV Curve ---  

Defects Summary

Defect Hybrid Results
- Munich
20220990107675
Module Results
- Munich
Module Results
- Prague CU 
(added to hybrid)
Comment (according to MPI)
Unbonded   4 4 (add 4)  
Low offset   0 1 add 69, before low gain
High offset 3 3 4 add 1468, before low gain
Low gain 2 4 6 (add 5) vanish 3, 11, 69, 1468
add 108, 128, 247, 339, 615, 617
(gain in MPI was also lower compared to neighbouring strips, but inside limits) 
High gain 2 2 2  
Stuck 3 3 3  
Dead 2 2 1 vanish 339, now low gain 
Partbonded   19   due to range change
Trim defects --   2 no trim results available for hybrid (no Freiburg data available)
Sum 12   21 + 2 (add 9)  

 


Module 20220990290407 - S002

Visual Inspection:

Comments:

Electrical Tests

Test Name Result  Comment
Long Term Test PASS  
FullBypassTest FAIL already on a hybrid
RedundancyTest PASS  
Pipeline Test PASS  
StrobeDelay PASS  
ThreePointGain FAIL 33 bad strips
TrimRangeScan FAIL 26 bad strips
ResponseCurve FAIL 33 bad strips
NO PASS  
TimeWalk PASS  
IV Curve PASS  

Defects Summary

Defect Hybrid Results
- Munich
20220990107658
Module Results
- Munich
Module Results
- Prague CU 
(added to hybrid)
Comment (according 
to MPI hybrid results)
Unbonded   3 4 (add 4)  
Low offset        
High offset 1   2 (add 1)  
Low gain     16 (add 16)  
High gain 1     c. 39 - ok in module test
Stuck 2   5 (add 3)  
Dead 2 24 3 (add 1)  
Noisy   1 3 (add 3)  
Trim defects -- 7 7 no trim results available for hybrid (no Freiburg hybrid data available)
Sum 6   33 + 7 (add 28,  1 disappeared)  

 


Module 20220990290408 - S003

Visual Inspection:

Comments:

Electrical Tests

Test Name Result  Comment
Long Term Test PASS  
FullBypassTest PASS  
RedundancyTest PASS  
Pipeline Test PASS  
StrobeDelay PASS  
ThreePointGain FAIL 17 bad strips
TrimRangeScan PASS  
ResponseCurve FAIL 17 bad strips
NO PASS  
TimeWalk PASS  
IV Curve PASS  

Defects Summary

Defect Hybrid Results
- Freiburg (DB)
20220553220603
Module Results
- Munich
Module Results
- Prague CU 
(added to hybrid)
Comments 
Unbonded   5 5 (add 5)  
Low offset        
High offset        
Low gain        
High gain        
Stuck 4 4 4  
Dead 8 8 8  
Noisy   15    
Trim defects 1   2 (add 1)  
Sum 13   19 (add 6)  

 


Module 20220990290409 - S004

Visual Inspection:

Comments:

Electrical Tests

Test Name Result  Comment
Long Term Test

PASS

 
FullBypassTest PASS  
RedundancyTest PASS  
Pipeline Test PASS  
StrobeDelay PASS  
ThreePointGain PASS  
TrimRangeScan PASS  
ResponseCurve PASS  
NO PASS  
TimeWalk PASS  
IV Curve PASS  

Defects Summary

Defect Hybrid Results
- Freiburg (DB)
20220553220704
Module Results
- Munich
Module Results
- Prague CU 
(added to hybrid)
Comments 
Unbonded        
Low offset   1 1 1077 - Dead in hybrid test
High offset        
Low gain 1 1 1  
High gain        
Stuck 3 3 3  
Dead 8 7 7  
Noisy   4 2 (add 2) according to MPI vanish 768, 1535 (due to different range)
both noisy channels are around the low gain channel (block of three bad channels)
Trim defects 3 --- 2 (1disappeared) vanish 1280
Sum 15   16 (add 2, 1 disappeared)  

 


Module 20220990290410 - S005

Visual Inspection:

Comments:

Electrical Tests

Test Name Result  Comment
Long Term Test

PASS

 
FullBypassTest PASS  
RedundancyTest PASS  
Pipeline Test PASS  
StrobeDelay PASS  
ThreePointGain FAIL 25 bad strips
TrimRangeScan FAIL 18 bad strips
ResponseCurve FAIL 24 bad strips
NO PASS  
TimeWalk PASS  
IV Curve PASS  

Defects Summary

Defect Hybrid Results
- Freiburg (DB)
20220553220701
Module Results
- Munich
Module Results
- Prague CU 
(added to hybrid)
Comments 
Unbonded   6 6 (add 6)  
Low offset        
High offset        
Low gain 4   10 (add 5) 66 dead on hybrid
add 915, 1362-1364, 1468
High gain        
Stuck 2   2  
Dead 7 14 6 MPI results: all defects from 3pg are summed here, added channel 0, missed 513, 915, 1468 
(according to Prague)
Noisy   2   767-768 - OK in Freiburg and Prague results
Trim defects 1 -- 2 (add 1)  
Sum 14   26 (add 12)