MPI/Prague CU Prequalification request

Part II (Prague CU)

September 12 2003

Documentation: Production WWW page

Link to MPI prequalification results

Results of module QA:

Modules tested:

Conclusion:

Two modules assembled in MPI were received in Prague. All Prague-relevant steps of QA document were performed. The conclusion is:
Module P004 fulfills all specifications required for prequalification, except for number of bad channels (bonds damaged during cleaning in MPI)
Module P005 fulfills all specifications required for prequalification

Summary:

P005: Detailed results

Comparison to the hybrid performance:

Test Name
Hybrid Results (Freiburg)
Module Results
Comment
Long Term Test
N/A
PASS

FullBypassTest PASS
PASS
RedundancyTest
PASS PASS
Pipeline Test
PASS PASS
StrobeDelay PASS
PASS

ThreePointGain
PASS (9 bad channels)
FAIL (21 bad channels) 12 added bad channels - in specs for prequalification
TrimRangeScan
FAIL
FAIL
1 untrimmable channel - already in a hybrid
ResponseCurve
PASS (9 bad channels)
FAIL (21 bad channels) 12 added bad channels - in specs for prequalification
NO PASS
PASS

TimeWalk PASS
PASS

IV Curve PASS
PASS


Grounding scheme:

Power cable shielded by Al foil connected to VME crate skeleton in point near module (using Cu thick wire), insulate from other modules, module box ungrounded

Signal cables 3m, recommended type

Bad channels:

all adding bad channels.......

 

P004: Detailed results

Comparison to the hybrid performance:

Test Name
Hybrid Results (Freiburg)
Module Results
Comment
Long Term Test
N/A
PASS

FullBypassTest PASS
PASS
RedundancyTest
PASS PASS
Pipeline Test
PASS PASS
StrobeDelay PASS
PASS

ThreePointGain
PASS (10 bad channels)
FAIL (40 bad channels) bondwires damaged during cleaning at MPI
TrimRangeScan
PASS
PASS

ResponseCurve
PASS (10 bad channels)
FAIL (40 bad channels) bondwires damaged during cleaning at MPI
NO PASS
PASS

TimeWalk PASS
PASS

IV Curve PASS
PASS

Grounding scheme:

Power cable shielded by Al foil un-connected to VME crate skeleton, insulate from other modules, module box ungrounded

Signal cables 5m, recommended type

Bad channels:

all adding bad channels.......

 

Database

All electrical QA data inserted - Link to All Tests Report
The Prague Team